Description

Category: Clamp Meter
Product Name: CMP-1006 Clamp-on Meter
Brand: SONEL
Packing Condition: Packed

Additional information

Weight 0.303 kg
CATEGORY

RANGE

1000 A

VOLTAGE

600 V

CURRENT

1000 A

FREQUENCY

30 Hz – 15 kHz

RESISTANCE

66 MOhm

MODEL

CMP-1006

BRAND

Specification

  • DC current measurement

    Range Resolution Accuracy
    0.0…659.9 A 0.1 A ±(2.5% m.v. + 5 digits)
    660…1000 A 1 A ± (2.8% m.v. + 8 digits)

    “m.v.” – measured value

     

    DC voltage measurement

    Range Resolution Accuracy
    0.000…6.599 V 0.001 V ±(1.5% m.v. + 3 digits)
    6.60…65.99 V 0.01 V ±(1.5% m.v. + 3 digits)
    66.0…600.0 V 0.1 V ±(1.5% m.v. + 3 digits)

    Resistance measurement

    Range Resolution Accuracy
    0.0…659.9 Ω 0.1 Ω ±(1.0% m.v. + 4 digits)
    0.660…6.599 kΩ 0.001 kΩ ±(1.5% m.v. + 2 digits)
    6.60…65.99 kΩ 0.01 kΩ ±(1.5% m.v. + 2 digits)
    66.0…659.9 kΩ 0.1 kΩ ±(1.5% m.v. + 2 digits)
    0.660…6.599 MΩ 0.001 MΩ ±(2.5% m.v. + 3 digits)
    6.60…66.00 MΩ 0.01 MΩ ±(3.5% m.v. + 5 digits)

    Duty cycle measurement

    Range Resolution Accuracy
    10.0%…94.9% 0.1% unspecificated
    • frequency range: 30 Hz…15 kHz

     

    AC current measurement (True RMS)

    Range Resolution Accuracy
    0.0…659.9 A 0.1 A ±(2.5% m.v. + 8 digits) for 45…65 Hz
    660…1000 A 1 A ±(2.8% m.v. + 8 digits) for 45…65 Hz

    AC voltage measurement (True RMS)

    Range Resolution Accuracy
    0.000…6.599 V 0.001 V ±(1.8% m.v. + 5 digits) for 45…65 Hz
    6.60…65.99 V 0.01 V ±(1.8% m.v. + 5 digits) for 45…65 Hz
    66.0…600.0 V 0.1 V ±(1.8% m.v. + 5 digits) for 45…65 Hz

    Frequency measurement

    Range Resolution Accuracy
    30.00…659.9 Hz 0.1 Hz ±(1.2% m.v. + 2 digits)
    0.660…6.599 kHz 0.001 kHz ±(1.2% m.v. + 2 digits)
    6.60…15.00 kHz 0.01 kHz ±(1.2% m.v. + 2 digits)

    sensitivity:

    30 Hz…5 kHz: 10 V RMS min

    5 kHz…15 kHz: 40 V RMS min. for 20…80% duty cycle

     

    Temperature

    Range Resolution Accuracy *
    -20…+760°C 1°C ±(3% m.v. + 5°C)
    -4…+1400°F 1°F ±(3% m.v. + 9°F)

    * probe accuracy not included