FLUKE FEV500 FAST DC CHARGING STATION ANALYZER, CCS2 Pro

Key Features

  • All-in-one Fast DC charger testing, no EV required
  • Guided Autotest with clear PASS/FAIL results
  • Simulates a 2 kW charging load safely
  • TruTest™ software for automatic reporting
  • Rugged, battery-powered for field mobility
SKU: 4695861fluke376fc-695866 Category: Tag:

Description

Category: E-Mobility
Product Name: FLUKE FEV500 FAST DC CHARGING STATION ANALYZER, CCS2 Pro
Brand: FLUKE
Model: FLK-FEV500/CCS2 Pro
Packing Condition: Packed
Lead Time:6-8 Weeks

Additional information

Weight26 kg
MODEL

FLK-FEV500/CCS2

RANGE

Multi

VOLTAGE

1000V

BRAND

CURRENT

20 MΩ

Specification

Specifications: Fluke FEV500 Fast DC EV Charging Station Analyzer

General Specifications
CaseRugged, wheeled hardcase
Dimensions65 cm x 50.8 cm x 30 cm (25.6 in x 20 in x 11.8 in)
Weight26 kg (57 lb)
Display7-in TFT, 1024 x 600 pixels, capacitive touch (operable with PPE gloves)
Ultra-bright, sunlight-readable display with up to 1,700 cd/m²
Brightness adjustment with ambient light sensor
InterfaceKeys: Power on/off, Backlight, Stop Test
LEDs: Power, Battery Status, Charging
Power
BatteryLithium-ion; 10.8 V, 6.8 Ah, 73.44 Wh (customer replaceable)
Runtime10 hours (battery recharges during test)
Charging TimeTypically 3 hours with USB-C PD 65 W charger
Backup DurationUp to 6 months before recharge
Interfaces
Wireless ConnectivityIntegrated Wi-Fi (802.11b/g/n) and Bluetooth 5.2 module
TX/RX Frequency Range: 2400 MHz to 2483.5 MHz
Transmit Operating Power: < 100mW
Encryption: WPA2-AES (WiFi), AES-CCM (Bluetooth)
(Activation subject to firmware support. Refer to release notes for availability.)
USB-CUSB 2.0 high-speed for data download to PC-software TruTest™ and calibration
Charging battery with USB-C power adapter PD 2.0 or higher with 9V 1.8 A
USB-C flash drive support for firmware updates
Max supply current: 900 mA
GNSSGlobal navigation satellite receiver with internal antenna for time synchronization
Fuse11 A (not customer replaceable)
WarrantyMain unit: 2 years
Battery and accessories: 1 year
Environmental Specifications
Operating Temperature-20 °C to +50 °C (-4 °F to +122 °F)
Battery Charging Temperature0 °C to +45 °C (32 °F to +113 °F)
Storage Temperature-20 °C to +60 °C (-4 °F to +140 °F); Recommended: 0 °C to +30 °C
Operating Humidity≤100% up to 30 °C; 55% at 40 °C; 35% at 50 °C
Operating AltitudeUp to 3000 m
Storage AltitudeUp to 12,000 m
VibrationIEC 60721-3-3 / 3M2
Drop Test0.5 m (visual defects allowed)
Ingress Protection (lid closed)IP54
Ingress Protection (lid opened)IP40 (protected against objects ≥1 mm)
Air-cooling plenum: IP20 (protected against objects ≥12.5 mm)
No protection against water ingress
Safety StandardIEC 61010-1, Pollution Degree 2
IEC 61010-2-034
Electrical Specifications
Auto-Test Sequence
Performed TestsCCS Low-Level Communication and SLAC Test, Continuity Test, Insulation Resistance Test, Load Test (including Cable Check Voltage Measurement), IMD Test, Redidual Voltage Test
Continuity Test (RLO)
MeasurementTest probe to PE pin of CCS 1/2 socket
Open-Loop VoltageMax 5 V
Test CurrentMax 10 A (up to 0.2 Ω)
Test MethodDC test with alternating polarity
Live Circuit DetectionInhibits test if test probe voltage > 60 V
Test Probe ZeroingSelect ZERO in user interface to zero the test probe resistance. 
StandardIEC61557-4
RLO RangeResolutionAccuracy
2 Ω<1Ω: 0.1 mΩ
≥1Ω: 0.0001Ω
≤ 20 mΩ: ± (8% + 0.8 mΩ)
≤ 200 mΩ: ± (4% + 4 mΩ)
> 200 mΩ: ± (4% + 40 mΩ)
Insulation Resistance (RISO)
MeasurementsInsulation Resistance DC+ to PE and DC- to PE
Test VoltageMax EVSE Voltage ≤ 500 V: 500 V +10% / -0%
Max EVSE Voltage > 500 V: 1000 V +10% / -0%
Max Short Circuit Current2 mA
StandardIEC61557-2
Test VoltageRISO RangeResolutionAccuracy
500 V10 kΩ to 20 MΩ0.01 MΩ± (5 % rdg + 2 digit)
1000 V10 kΩ to 20 MΩ0.01 MΩ± (5 % rdg + 2 digit)
CCS Communication Test – Control Pilot (CP)
ParametersVoltage CP high, Voltage CP low, Frequency, Duty Cycle
Simulation of statesA, B, C, D, E (simulation and validation)
Digital ProtocolDIN SPEC 70121, ISO 15118
ParameterRangeResolutionAccuracy
CP High, CP Low-15 V to +15 V0.01 V± (0.4 % rdg + 2 digit)
FrequencyDC, 900 to 1100 Hz1 Hz0.1 % rdg or 1 digit
Duty Cycle2 to 98 %0.10%± 5 digit
SLAC0 dB to 20 dB1 dB
CCS Communication Test – Proximity Pilot (PP)
ParameterRangeResolutionAccuracy
PP Resistor50.0 to 499.9 Ω0.1  Ω± 0.5 %
500 to 5000 Ω1 Ω
Load Test
ParametersCable Check Voltages: VDC+ to PE, VDC- to PE
Load Test: Voltage DC+ to DC-, Current, Power, Duration
ParameterRangeResolutionAccuracy
Voltage1000 V0.1 V± (0.2 % rdg + 4 digit)
Current10 A0.01 A± (0.5% rdg + 5 digit)
Power0 to 3.75 kW0.001 kW± (0.7% rdg + 15 digit)
Insulation Monitoring Device (IMD) Test
Auto-TestNo trip test, trip test
Test Resistor no trip test: 250 kΩ (DC+ to PE)
Test Resistor trip test: 95 kΩ (max. EVSE Voltage >500 V dc), 45 kΩ (max. EVSE Voltage ≤500 V dc) (DC- to PE)
Duration: max 15 s for each test
Test Resistor Range19.5 kΩ to 3 MΩ, 256 values
StandardIEC61557-8 / IEC 61557-18

Download

 

Models

FLK-FEV500/CCS2 PRO

Fluke FEV500 Fast DC EV Charging Station Analyzer with TruTest™ Software License

Includes:

  • FEV500 Analyzer
  • TP165X remote control probe
  • Li-ion Battery
  • USB-C to USB-A cable
  • TruTest™ Software License

Reviews

There are no reviews yet.

Be the first to review “FLUKE FEV500 FAST DC CHARGING STATION ANALYZER, CCS2 Pro”