FLK-3000FC – Fluke 3000 FC Series Wireless Multimeter -FLUKE
Description
Category: Multimeter
Product Name: Fluke 3000 FC Series Wireless Multimeter
Brand: FLUKE
Packing Condition: Packed
Additional information
| Weight | 0.75 kg |
|---|---|
| CATEGORY | |
| RANGE | Multi |
| VOLTAGE | 1000 V |
| CURRENT | 400 mA |
| FREQUENCY | 99.99 kHz |
| RESISTANCE | 50 MOhm |
| CAPACITANCE | 9999 µF |
| MODEL | Fluke 3000 FC |
| BRAND |
Specification
Specifications: Fluke FC 3000 Wireless Multimeter
For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).
| Detailed Specifications | ||||||
| AC Voltage | ||||||
| Range ¹ / Resolution | 600.0 mV / 0.1 mV 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V | |||||
| Accuracy ², ³ | 45 Hz to 500 Hz | 1.0 % + 3 | ||||
| 500 Hz to 1 kHz | 2.0 % + 3 | |||||
| ¹ All AC voltage ranges are specified from 1 % of range to 100 % of range. ² Crest factor of ≤ 3 at full scale p to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V. ³ For non-sinusoidal waveforms, add –(2 % of reading + 2 % full scale) typical, for crest factor up to 3. | ||||||
| DC Voltage, Continuity, Resistance, Diode Test and Capacitance | ||
| Function | ||
| mV | Range ¹ / Resolution | 600.0 mV / 0.1 mV |
| Accuracy | 0.09 % + 2 | |
| V | Range ¹ / Resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V |
| Accuracy | 0.09 % + 2 0.15 % + 2 | |
| ))) | Range ¹ / Resolution | 600 Ω / 1 Ω |
| Accuracy | Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer. | |
| Ω | Range ¹ / Resolution | 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 60.00 kΩ / 0.1 kΩ 600.0 kΩ / 0.001 MΩ 50.00 MΩ / 0.01 MΩ |
| Accuracy | 0.5 % + 2 0.5 % + 1 1.5 % + 3 | |
| Diode test | Range ¹ / Resolution | 2.000 V0.001 V |
| Accuracy | 1 % + 2 | |
| μF | Range ¹ / Resolution | 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF ¹ / 1 μF |
| Accuracy | 1.2 % + 2 10 % | |
| ¹ In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2. | ||
| AC and DC Current | ||
| Function | ||
| mA AC (45 Hz to 1 kHz) | Range ¹ / Resolution | 60.00 mA / 0.01 mA 400.0 mA ³ / 0.1 mA |
| Accuracy | 1.5 % + 3 | |
| mA DC ² | Range ¹ / Resolution | 60.00 mA / 0.01 mA 400.0 mA / 0.1 mA |
| Accuracy | 0.5 % + 3 | |
| ¹ All AC current ranges are specified from 5 % of range to 100 % of range. ² Input burden voltage (typical): 400 mA input 2 mV/mA. ³ 400.0 mA accuracy specified up to 600 mA overload. | ||
| Frequency | ||
| Range ¹ / Resolution | 99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz 9.999 kHz / 0.001 kHz 99.99 kHz / 0.01 kHz | |
| Accuracy | 0.1 % + 1 | |
| ¹ Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps. | ||
| Input Characteristics | ||
| Function | ||
![]() | OverloadProtection | 1100 V RMS |
| Input Impedance (nominal) | > 10 MΩ < 100 pF | |
| Common Mode Rejection Ratio (1 kΩ unbalance) | > 120 dB at DC, 50 Hz or 60 Hz | |
| Normal Mode Rejection | > 60 dB at 50 Hz or 60 Hz | |
![]() | OverloadProtection | 1100 V RMS |
| Input Impedance (nominal) | > 10 MΩ < 100 pF | |
| Common Mode Rejection Ratio (1 kΩ unbalance) | > 60 dB, DC to 60 Hz | |
![]() | OverloadProtection | 1100 V RMS |
| Input Impedance (nominal) | > 10 MΩ < 100 pF | |
| Common Mode Rejection Ratio (1 kΩ unbalance) | > 120 dB at DC, 50 Hz or 60 Hz | |
| Normal Mode Rejection | > 60 dB at 50 Hz or 60 Hz | |
| Open circuit test voltage | ||
![]() | OverloadProtection | 1100 V RMS |
| Input Impedance (nominal) | < 2.7 V DC | |
| Full scale | To 6 MΩ: < 0.7 V DC 50 MΩ: < 0.9 V DC | |
| Typical short circuit current | < 350 mA | |
![]() | OverloadProtection | 1100 V RMS |
| Input Impedance (nominal) | < 2.7 V DC | |
| Full scale | To 6 MΩ: 2.000 V DC | |
| Typical short circuit current | < 1.1 mA | |
| mA | Overload Protection | Fused, 44/100 A, 1000 V FAST Fuse |
| Overload | 600 mA overload for 2 minutes maximum, 10 minutes rest minimum | |
| MIN/MAX Recording | ||
| DC functions | The specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration | |
| AC functions | The specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration | |
| General Specifications | |
| Maximum voltage between any terminal and earth ground | 1000 V DC or AC RMS |
| Ω fuse protection from A inputs | 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only |
| Display (LCD) | Update rate: 4/sec Volts, amps, ohms: 6000 counts Frequency: 10,000 counts Capacitance: 1,000 counts |
| Battery type | Three AA Alkaline batteries, NEDA 15A IEC LR6 |
| Battery life | 300 hours minimum |
| Temperature | Operating: -10 °C to 50 °C Storage: -40 °C to 60 °C |
| Relative humidity | 0 % to 90 % (0 °C to 35 °C) 0 % to 75 % (35 °C to 40 °C) 0 % to 45 % (40 °C to 50 °C) |
| Altitude | Operating: 2,000 m Storage: 12,000 m |
| Temperature coefficient | 0.1 X (specified accuracy) / °C (< 18 °C or > 28 °C) |
| Wireless frequency | 2.4 GHz ISM Band 20 meter range |
| Size (H x W x L) | 4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in) |
| Weight | 340 g (12 oz) |
| Safety standards | US ANSI: ANSI/ISA 61010-1 / (82.02.01): 3rd edition CSA: CAN/CSA-C22.2 No 61010-1-12: 3rd edition CE European: IEC/EN 61010-1:2010 |
| Electromagnetic compatibility EMI, RFI, EMC, RF | EN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID : T68-FWCS IC:6627A-FWCS |
| Ingress Protection (IP) rating | IP54 |