5112860 – Fluke-417D/62Max Kit, 417D Laser Distance Meter and 62Max+ IR Thermometer -FLUKE

299.32$ VAT included

Out of stock

SKU: 87dca20a61a4 Categories: , Brand:

Description

Category: Preventative Maintenance Tools
Product Name: Fluke-417D/62Max Kit, 417D Laser Distance Meter and 62Max+ IR Thermometer
Brand: FLUKE
Packing Condition: Packed

Additional information

Weight 0.95 kg
CATEGORY

RANGE

0.2-40 m

TEMPERATURE

-30°C to 650°C

MODEL

FLUKE-417D/62MAX KIT

BRAND

Specification

Specifications: Fluke 417D Laser Distance Meter / 62 MAX+ IR Thermometer Kit

Fluke 417D Laser Distance Meter

417D
Typical range [1] 0.2-40 m/0.6-131 ft
Typical measuring tolerance* [1] 2.0 mm ± 1.5 mm/± 0.06 in ***
Maximum measuring tolerance [2] ± 3.0 mm/0.12 in ***
Accuracy up to 10m (+/-) ± 2 mm
Display 2 line/1 mm/1/32 in
Display illumination Yes
Laser point at distance 6/30/60 mm (10/40/100 m)
Area Yes
Units setting (smallest units displayed) 0,000m, 0′ 00” 1/32, 0 in 1/32
Auto laser switch off 90 sec
Auto power switch off 180 sec
General
Laser class II
Laser type 635 nm, <1 mW
Protection class IP54
Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03 Up to 3,000 measurements
Size (Hx W x D) 11.9 x 3.8 x 2.6 cm
Drop test 1 meter
Weight (with batteries) 95g (3.35 oz)
Temperature range: Storage -25 °C to 70 °C (-13 °F to 158 °F)
Temperature range: Operation -10 °C to 50 °C (14 °F to 122 °F)
Calibration cycle Not applicable
Maximum relative humidity 85 % @ 20°F to 120 °F
(-7 °C to 50 °C)
Safety CAN/CSA-C22.2 No. 61010-1-04, UL Std. No. 61010-1 (2nd Edition), ISA-82.02.01, IEC Standard No. 61010-1:2001, EN60825-1:2007 (Class II)
EMC 61326-1:2006

[1] Applies for 100 % target reflectivity (white painted wall), low background illumination, 25 °C (13 °F).

[2] Applies for 10 % to 500 % target reflectivity, high background illumination, -10 °C to +50 °C (14 °F to +122 °F).

[3] Tolerances apply from 0.05 m to 10 m (0.001 ft to 32.8 ft) with a confidence level of 95 %. The maximum tolerance may deteriorate to 0.1 mm/m (0.003 in/ft) between 10 m to 30 m (32.8 ft to 98.4 ft) and to 0.15 mm/m (0.005 in/ft) for distances above 30 m (98.4 ft).

[4] Applies for 100 % target reflectivity, background illumination between 10,000 lux and 30,000 lux.

[5] After user calibration. Additional angle related deviation of ± 0.01° per degree up to ± 45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ± 0.1°.

Fluke 62 MAX+ IR Thermometer

62 MAX+
Temperature range – 30 °C to 650 °C
(-22 °F to 1202 °F)
Accuracy (Calibration geometry with ambient temperature 23 °C +/- 2 °C) ± 1.0 °C or ± 1.0 % of reading, whichever is greater
± 2.0 °C at -10 °C to 0 °C
± 3.0 °C at -30 °C to -10 °C
Optical resolution 12:1
(calculated at 90 % energy)
Response time (95 %) < 300 ms (95 % of reading)
Spectral response 8 to 14 microns
Emissivity 0.10 to 1.00
Display resolution 0.1 °C (0.2 °F)
Repeatability (% of reading) ± 0.5 % of reading or ± 0.5 °C (whichever is greater)
Power 1 AA alkaline battery
Battery life 8 hours with laser and backlight on
Weight 255 g (8.99 oz)
Size (175 x 85 x 75) mm
(6.88 x 3.34 x 2.95) inches
Operating temperature 0 °C to 50 °C
(32 °F to 122°F)
Storage temperature -20 °C to 60 °C
(-4 °F to 140 °F)
(without battery)
Operating humidity Non- condensing @ ≤ 10 °C (50 °F)
≤ 90 % RH @ 10 °C (50 °F) to 30 °C (86 °F)
≤ 75 % RH @ 30 °C (86 °F) to 40 °C (104 °F)
≤ 45 % RH @ 40 °C (104 °F) to 50 °C (122 °F)
Operating altitude 2000 meters above mean sea level
Storage altitude 12,000 meters above mean sea level
Drop test 3 meters
Implement standard Q/ASF01
Standards and agency approval
Compliance IEC 61010-1: Pollution Degree 2
Laser safety IEC 60825-1 Class 2, 650 nm, < 1 mW
Ingress protection rating IP 54 per IEC 60529
Warranty 3 years

Download

Video

Reviews

There are no reviews yet.

Be the first to review “5112860 – Fluke-417D/62Max Kit, 417D Laser Distance Meter and 62Max+ IR Thermometer -FLUKE”

Your email address will not be published. Required fields are marked *