4984691 – FLUKE-MDA-510 Motor Drive Analyzer 510, 4-channel color -FLUKE

SKU: 989ef1f91ea9 Category: Brand:

Description

Category: Power Quality
Product Name: FLUKE-MDA-510 Motor Drive Analyzer 510, 4-channel color
Brand: FLUKE
Packing Condition: Packed

Additional information

Weight15 kg
CATEGORY

RANGE

Multi

VOLTAGE

1000 V

CURRENT

6000 A

FREQUENCY

500 MHz

MODEL

FLUKE-MDA-510

BRAND

Specification

Specifications: Fluke MDA-510 and MDA-550 Motor Drive Analyzers
Measurement Function
DC voltage (V dc)
Maximum voltage with 10:1 or 100:1 probe1000 V
Maximum resolution with 10:1 or 100:1 probe1 mV
Full scale reading999 counts
Accuracy at 4 s to 10 us/div±(3 % + 6 counts)
AC voltage (V ac)
Maximum voltage with 10:1 or 100:1 probe1000 V
Maximum resolution with 10:1 or 100:1 probe1 mV
Full scale reading999 counts
50 Hz±(3 % + 10 counts) – 0.6 %
60 Hz±(3 % + 10 counts) – 0.4 %
60 Hz to 20 kHz±(4 % + 15 counts)
20 kHz to 1 MHz±(6 % + 20 counts)
1 MHz to 25 MHz±(10 % + 20 counts)
True-rms voltage (V ac+dc)
Maximum voltage with 10:1 or 100:1 probe1000 V
Maximum resolution with 10:1 or 100:1 probe1 mV
Full scale reading1100 counts
DC to 60 Hz±(3 % + 10 counts)
60 Hz to 20 kHz±(4 % + 15 counts)
20 kHz to 1 MHz±(6 % + 20 counts)
1 MHz to 25 MHz±(10 % + 20 counts)
PWM voltage (V pwm)
PurposeTo measure on pulse width modulated signals, like motor drive inverter outputs
PrincipleReadings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency
AccuracyAs Vac+dc for sinewave signals
Peak voltage (V peak)
ModesMax peak, min peak, or pk-to-pk
Maximum voltage with 10:1 or 100:1 probe1000 V
Maximum resolution with 10:1 or 100:1 probe10 mV
Accuracy
Max peak, min peak±0.2 division
Pk-to-pk±0.4 division
Full scale reading800 counts
General Specification
Current (AMP) with current clamp
RangesSame as V ac, Vac+dc or V peak
Scale Factors0.1 mV/A, 1 mV/A, 10 mV/A, 20 mV/A, 50mV/A, 100 mV/A, 200 mV/A, 400 mV/A
AccuracySame as Vac, Vac+dc or V peak (add current clamp accuracy)
Frequency (Hz)
Range1.000 Hz to 500 MHz
Full scale reading999 counts
Accuracy±(0.5 % + 2 counts)
Voltage/Herz ratio (V/Hz)
PurposeTo show the measured V PWM value (see V PWM) divided by the fundamental frequency on variable ac motor speed drives
Accuracy% Vrms + % Hz
Voltage unbalance drive input
PurposeTo show the highest percentage difference of one of the phase vs average of the 3 true-rms voltages
AccuracyIndicative percentage based on Vac+dc values
Voltage unbalance drive output and motor input
PurposeTo show the highest percentage difference of one of the phase vs average of the 3 PWM voltages
AccuracyIndicative percentage based on V PWM values
Current unbalance drive input
PurposeTo show the highest percentage difference of one of the phase vs average of the 3 AC current values
AccuracyIndicative percentage based on Aac+dc values
Current unbalance drive output and motor input
PurposeTo show the highest percentage difference of one of the phase vs average of the 3 AC current values
AccuracyIndicative percentage based on A ac values
Rise and fall time
ReadingsVoltage difference (dV), time difference (dt), voltage vs time difference (dV/dt), overshoot
AccuracyAs oscilloscope accuracy
Harmonics and spectrum
HarmonicsDC to 51st
Spectrum ranges1…9 kHz, 9-150 kHz (20 MHz filter on), up to 500 MHz (voltage modulation)
Shaft voltage
Events / secondIndicative percentage based on rise and fall time (Impulse discharges) measurements
Report data capture
Number of screensTypical 50 screens can be saved in reports (depends on compression ratio)
Transfer to PCUsing 2 GB USB stick or mini-USB to USB cable and FlukeView™ 2 for ScopeMeter™ test tool
Probe settings
Voltage probe1:1, 10:1, 100:1, 1000:1, 20:1, 200:1
Current clamp0.1 mV/A, 1 mV/A, 10 mV/A, 20 mV/A, 50 mV/A, 100 mV/A, 200 mV/A, 400 mV/A
Shaft voltage probe1:1, 10:1, 100:1