4377198 – 6200-2 UK KIT Portable Appliance Tester, Kit, Uk -FLUKE

1,536.74$ 5% VAT included

In stock

SKU: 702aec6e8547 Categories: , Brand:

Description

Category: Electrical Tester
Product Name: 6200-2 UK KIT Portable Appliance Tester, Kit, Uk
Brand: FLUKE
Packing Condition: Packed

Additional information

Weight10 kg
CATEGORY

RANGE

Multi

VOLTAGE

90V – 264V

CURRENT

0 – 13 A

RESISTANCE

0 – 299 MOhm

MODEL

6200-2 UK KIT

BRAND

Specification

Specifications: Fluke 6200-2 Portable Appliance Testers

Specifications
Test specificationsThe accuracy specification for the display range is defined as ±(%reading + digit counts) at 23 °C ±5 °C, ≤75% RH.
Between 0 °C and 18 °C and between 28 °C and 40 °C, accuracy specifications may degrade by 0.1 x (accuracy specification) per °C.
The measurement range meets the service operating errors specified in EN61557-1: 1997, EN61557-2: 1997, EN61557-4: 1997, EN61557-6: 1997, DIN VDE0404-2.
Power-on testThe test indicates reversed L-N, missing PE, and measures the mains voltage and frequency.
Display range90 V to 264 V
Accuracy at 50 Hz±(2% + 3 counts)
Resolution1 V
Input impedance> 1 MΩ // 2.2 nF
Maximum input mains voltage264 V
Earth bond test (R pe)Display Range0 to 19.99 Ω
Accuracy (after bond test zeroing)±(2.5% + 4 counts)
Resolution0.01 Ω
Test current200 mA AC -0% +40% into 1.99 Ω
25 A AC ±20% into 25 mΩ at 230 V
Open circuit voltage> 4 V AC, < 24 V AC
Bond test zeroingcan subtract up to 1.99 Ω
Insulation test (R iso)Display range0 to 299 MΩ
Accuracy±(5% + 2 counts) from 0.1 to 300 MΩ
Resolution0.01 MΩ (0 to 19.99 MΩ)
0.1 MΩ (20 to 199.9 MΩ)
1 MΩ (200 to 299 MΩ)
Test voltage500 V DC -0% + 10% at 500 kΩ load
Test current> 1 mA at 500 kΩ load, < 15 mA at 0 Ω
Auto discharge time< 0.5 s for 1 μF
Max. capacitive loadOperational up to 1 μF
Touch current testDisplay range0 to 1.99 mA AC
Accuracy±(4% + 2 counts)
Resolution0.01 mA
Internal resistance (via probe)2 kΩ
Measuring methodProbe*
Substitute leakage current testDisplay range0 to 19.99 mA AC
Accuracy±(2.5% + 3 counts)
Resolution0.01 mA
Test Voltage100 V AC ±20%
Load/leakage test: load currentDisplay range0 A to 13 A
Accuracy±(4% + 2 counts)
Resolution0.1 A*
Load/leakage test: load powerDisplay range 230 V Mains0.0 VA to 3.2 kVA
Accuracy±(5% + 3 counts)
Resolution1 VA (0 to 999 VA), 0.1 kVA (>1.0 kVA)*
Load/leakage test: leakage currentDisplay range0 to 19.99 mA
Accuracy±(4% + 4 counts)
Resolution0.01 mA*
PELV testAccuracy at 50 Hz±(2% + 3 counts)
Overload protection300 V rms
Warning threshold25 V rms
*The appliance under test is energized at mains potential.

Environmental specifications
Operating temperature0 to 40 °C
Relative humidityNon condensing <10 °C
95% from 10 to 30 °C
75% from 30 to 40 °C

Safety specifications
Safety ratingComplies with EN61010-1 3rd edition
CAT II, 300 V, pol 2

Mechanical and general specifications
Size (L x W x H)200 x 275 x 114 mm
Weight3.13 kg
Power supply230 V +10% -15%, 50 Hz ±2
Power consumption (tester)13 W typical (idle)
60 W max. during 25A Bond test
StorageTemperature-10 to 60 °C
Corrosion70 °C @ 95% RH for 5 days max.
Operating altitude0 up to 2000 m
SealingIP-40 (enclosure), IP-20 (connectors)
EMCComplies with EN61326-1, portable
EMI Immunity3 V/m

Download